We take a bottom-line approach to each project. Our clients consistently see increased traffic, enhanced brand loyalty and new leads thanks to our work.
The radiographic method (RT) makes use of a ionizing radiation beam directed towards the piece to be examined in order to highlight any superficial and internal imperfections. Part of the radiation is absorbed through the piece depending of the material chemical-physical characteristics. When the beam finds a discontinuity, the absorption is different and creates a contrast with the surrounding material on a suitable means of detection.
The most common type of radiation sources are:
The radiographic testing is applied in almost all fields in which Metalprove S.r.l. works, with the authorization by Ministerial Decree for the road transportation of radioactive substances throughout the national territory and with Prefectural Decree for the detention and use of radioactive sources.
The company has radioisotopes of iridium (Ir-192) and selenium (Se-75) and X-ray tubes of various powers, which are used in many applications according to European standards (EN ISO 5579, EN ISO 17636-1 , EN ISO 10675, EN ISO 4993, EN 12681, etc.), American standards (ASME Sec. V, ASME Sec. VIII, ASTM E94, ASTM E155, ASTM E186, ASTM E446, etc.) or customer specifications (SAL SNAM , etc.).